Manitowoc RF0300 Especificações Página 42

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 41
42 Part Number 000007661 6/12
RF0300/RFS0300
Self-Contained Air-Cooled
When the toggle switch is placed in the “ON” position
the following controls must be in the closed position
before the ice machine will start:
A. Bin Thermostat
B. Low Evaporator Temperature Thermostat
C. Ice Chute Safety Switch
D. Low Water Level Switch
Placing the toggle switch in the ON position starts the
gear motor and a 10 minute compressor time delay.
The compressor starts and the float valve controls the
water inlet valve and water level. The freeze cycle
ends when ice contacts the bin thermostat. The ice
machine remains off until ice no longer contacts the
bin thermostat.
NOTE: Refer to electrical flowchart for “RF0300/
RFS0300 Air & Water” on page 57 for Sequence of
Operation detail.