Manitowoc S model Especificações Página 138

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 137
138 Part Number 80-1230-9 10/10
Ice machine stops, and can be restarted by
moving the toggle switch to OFF and back to
ICE.
The SafeGuard feature is stopping the ice
machine.
Refer to “SafeGuard Modes”.
Ice quality is poor.
Poor incoming water quality.
Test the quality of the incoming water and
check filter.
Water filtration is poor. Replace the filter.
Water softener is working improperly
(if applicable).
Repair the water softener.
Incoming water supply temperature is above
90°F (32.2°C).
Correct water temperature (verify check/
mixing valves in other equipment is working
properly). Connect ice machine to a cold
water supply.
Water pressure is low
Water pressure must remain between 20 and
80 psig.
Problem Possible Cause To Correct
Vista de página 137
1 2 ... 133 134 135 136 137 138 139 140 141 142 143 ... 291 292

Comentários a estes Manuais

Sem comentários